AnyCheck is a compact implant stability meter designed to provide fast and convenient assessment of implant stability using a controlled tapping method.

Unlike RFA-based systems that require a separate SmartPeg, AnyCheck measures directly through the healing abutment, Multi-Unit Abutment (MUA), or restoration, allowing stability measurements without removing and reconnecting prosthetic components.

Results are displayed as an IST (Implant Stability Test) value in under 3 seconds, providing clinicians with an immediate indication of implant stability.

Key Benefits

  • Direct tapping measurement
  • No SmartPeg required
  • No ongoing SmartPeg consumable cost
  • Results displayed in under 3 seconds
  • Measure without removing the healing abutment
  • Suitable for healing abutments, MUAs and restorations
  • Can also assess natural tooth mobility and prosthesis stability
  • Colour-coded IST display for quick interpretation
  • Compact and lightweight design
  • Automated safety mode for low-stability implants

Clinical Applications

Primary Stability Assessment
Measure implant stability immediately following implant placement to establish a baseline and assess initial stability.

Secondary Stability Monitoring
Monitor changes in implant stability throughout the osseointegration period using serial IST measurements.

Loading Decision Support
IST measurements can assist clinicians when assessing implant stability before conventional or immediate prosthetic loading.

Full-Arch & All-on-X Cases
Direct measurement through Multi-Unit Abutments allows efficient stability assessment of multiple implants without removing the prosthetic components.

Peri-implant & Maintenance Assessment
Stability can be monitored through existing restorations during recall and maintenance appointments.

Natural Teeth & Prostheses
The tapping method can also be used to assess natural tooth mobility and prosthesis stability.

No SmartPeg Required

AnyCheck measures implant stability by tapping directly against the existing healing abutment, MUA or restoration.

There is no need to install and remove a separate transducer peg for every measurement.

This simplifies the clinical workflow while eliminating SmartPeg inventory and ongoing consumable costs.

Fast Measurement

The automated tapping cycle provides an IST result in under 3 seconds.

Simply position the tapping rod correctly against the abutment and activate the measurement.

NEO IST Value

Results are displayed using the IST scale from 1–99 with an easy-to-read colour indication:

  • Red: 1–59 – Lower stability
  • Orange: 60–64 – Intermediate stability
  • Green: 65–99 – Higher stability

The colour-coded display allows rapid visual interpretation during clinical use.

Intelligent Safety Mode

Under normal conditions, AnyCheck performs 6 controlled tapping strokes.

When an IST value of 59 or below is detected, the safety mechanism restricts the measurement cycle to 2 taps, reducing unnecessary tapping on an implant with lower stability.

LCD Display

The integrated LCD screen displays the measured IST value immediately after the tapping cycle.

The colour-coded interface allows the clinician to quickly identify the measured stability range.

Simple Operation

AnyCheck features a straightforward operating system with dedicated ON/OFF and START controls.

Its compact design and weight of approximately 100 g make it easy to handle and position during implant assessment.

Tapping Rod Front Guide

The front guide assists with positioning the tapping rod against the healing abutment.

For consistent measurements, the tapping rod should contact the upper surface of the abutment with light contact and be positioned appropriately relative to the implant.

Technical Specifications

Product: AnyCheck
Manufacturer: NeoBiotech Co., Ltd.
Device Type: Dental Implant Stability Meter
Measurement Method: Controlled tapping motion
Measurement Scale: IST 1–99
Dimensions: 207 × 34.5 × 32 mm
Weight: 100 g
Measurement Accuracy: ±3
Hitting Speed: 0.5 seconds per stroke
Hitting Strength: 2.2 N
Normal Measurement: 6 strokes
Safety Mode: Automatically limited to 2 taps for IST ≤59
Hitting Angle: 0°–90°
Battery: 420 mA
Connection: USB Type-C
Infection Control: Disposable LDPE tapping rod cover
Manufacturer: NeoBiotech Co., Ltd.
Country of Origin: Korea

Recommended Measurement Technique

  • Switch the device on and position the tapping rod before starting the measurement.
  • Place the tapping rod lightly against the upper surface of the healing abutment.
  • Do not apply additional downward pressure.
  • Maintain the device approximately 0–30° upward from horizontal.
  • Position the tapping rod appropriately against the implant/abutment before activating the measurement.
  • Read the colour-coded IST result and numerical value after completion.

Healing Abutment Height Correction

AnyCheck IST measurements are calibrated using a 4 mm healing abutment.

When using different abutment heights, the following correction can be applied:

Healing Abutment HeightIST Correction
7 mmDisplayed IST + 6
6 mmDisplayed IST + 4
5 mmDisplayed IST + 2
4 mmNo correction
3 mmDisplayed IST − 2
2 mmDisplayed IST − 4
1 mmDisplayed IST − 6

Important

AnyCheck is intended for use by trained dental professionals.

Use a new disposable tapping rod cover for each patient to minimise the risk of cross-contamination.

Do not apply excessive pressure to the healing abutment during measurement.

Always refer to the manufacturer's Instructions for Use for complete operating instructions, indications, contraindications, cleaning, maintenance and safety information.